NIRScout Advantages

The NIRScout is user-friendly, modular, and a robust functional near-infrared spectroscopy (fNIRS) platform which measures hemodynamic responses to neuroactivation via oxy-, deoxy-, and total hemoglobin changes in the cerebral cortex. The NIRScout platform includes a host of ready-to-implement upgrades and modules to meet the needs of a broad range of cognitive neuroscience applications.

NIRScout (NSC) Advantages:

  • Ability to measure both topographic and tomographic measurements, can freely place probes anywhere on the cortex.
  • Modular design allows for easy and efficient upgrades and increased coverage, when needed.
  • Hyperscanning: single system can synchronously collect measurements from multiple participants simultaneously.
  • Illumination pattern (source firing sequence) fully customizable, which increases sampling rate, and prevents crosstalk.
  • Up to 255 triggers input, and up to 255 triggers output.

NIRScout Extended Plus (NSXP) Advantages:

  • Can be configured to use laser sources, LED sources, or both, depending on your research needs.
  • Fiber based system allows for safe data collection within MR.
  • Ability to use 4-wavelength and 8-wavelength sources. Used for detecting additional chromophores beyond hemoglobin (i.e. Cytochrome c oxidase).
  • Flat fibers and optodes allow for data collection for concurrent TMS and fNIRS applications.
  • Has expanded coverage, beyond our standard NIRScout system.

Functionality

The NIRScout is our most versatile lab based system.

The NIRScout is our most versatile lab based system.

Set up fNIRS Fast
NIRx uses the NIRScap and proprietary signal optimization procedure for an incredibly fast setup (see video of <60-second setup).

High data quality

Sampling rate of 100Hz, sensitivity of SiPD: < 1 pW or APD: 0.5pW, with a high dynamic range of 90 dBopt.

Multi-Modal Integration
NIRScout is ideal for multi-modal measurements with EEG, fMRI, eye-tracking, cochlear implants, TMS, tDCS, EMG, and other modalities for concurrent measurements.

Application-Specific Probes & Headgear

Specialized probes and headgear available for comfortable
measurements on any subject, for any application. Including for measurements on infants and children.

Technical Specifications

Sources NSC 8 to 16 LED sources
NSX 8 to 64 LED sources- single system
NSX 8 to 128 LED sources – tandem configuration
NSXP 8 to 64 LED sources – single system
NSXP 8 to 128 LED sources – tandem configuration
NSXP 8 to 32 Laser sources – single system
NSXP 8 to 64 Laser sources – tandem configuration
Detectors NSC 4 to 24 detectors
NSX 4 to 32 detectors – single system
NSX 4 to 64 detectors – tandem configuration
NSXP 4 to 32 detectors- single system
NSXP 4 to 64 detectors – tandem configuration
Source Illumination Types Hybrid Choice: LED & Laser Sources
Source Wavelengths LED: 760nm & 850nm; Laser: 785, 808, 830, & 850nm
Detection Sensor Silicon Photodiode (SiPD) or Avalanche Photodiode (APD)
Detector Dynamic Range 90 dBopt
Detector Sensitivity < 1 pW or APD: 0.5pW
Optode type Single-tip, or specialized Dual-tip optodes (faster set-up time and better contact to skin), Blunt-Tip (infant and child applications, better comfort)
Maximum Data Channel Stream 2048 (up to 4096 in tandem config.)
Multi-distance/Short-distance detectors Yes
Sampling Rate 2.5 – 100 Hz
Spectroscopic Technique, Phase Type Continuous Wave, Single Phase
3D Depth-discrimination Yes
Maximum Functional Resolution 7.5mm (with 7.5mm source-detector spacing)
Key Measurement Features Time multiplexing and 10e9 dynamic gain state switching
Hyperscanning Configuration Up to 4 separate bi-lateral 16-source/8-detector arrays for 4 subjects
Included Data Acquisition Software NIRStar
Topography Software Open format: nirsLAB, Homer2, MATLAB, etc.
Trigger/Event Connection Extended: 8-bit TTL Input and Output; Standard: 4-bit TTL Input
Headgear NIRScaps: freely-configurable, measures whole head, fits all age ranges, multi-modal
BCI/Neurofeedback Optional module for NIRStar
Multi-modal Compatibility Built-in: EEG, tDCS/TES, eye-tracking, motion-tracking
Requiring module: fMRI, MEG, TMS
Multi-distance/Short-distance detectors Yes, split one detector channel into 8 short channels
Included Accessories NIRScaps, System carrying case, strain-relief arms, Trigger cable, Instrument PC
Optional Accessories Computer cart, Active Trigger Splitter, fMRI/TMS compatibility, flat and blunt tipped optode, Animal fNIRS Module, BCI/neurofeedback – fully compatible with Turbo Satori software
Temperature Range 10 – 40 C (operating), -15 – 70 C (storage)
Humidity 20% – 80% Relative, Non-condensing
Power Supply Voltage and Consumption 90 to 250 VAC (50Hz – 60Hz); 175W Max
Dimensions (WxHxL), Net Weight Standard: 260mm x 170mm x 330mm, 10kg
Extended: 340mm x 170mm x 370mm, 16kg

 

Manufacturer

nirx

Request for Quote

Please fill in as much details as possible and we will take care of your request as soon as possible

*Required field