ibidi µ-Slide 18 Well

Eighteen wells on a standard 25.5 x 75.5 mm slide footprint, 100 µl and 0.34 cm² each, on a #1.5 polymer coverslip bottom. Eighteen conditions or six in triplicate, stained in the wells and imaged in one pass with no coverslipping and no cells lost in transfer.

ibidi µ-Slide 18 Well

What is the µ-Slide 18 Well?

Eighteen wells on a standard microscope slide footprint, 25.5 x 75.5 mm. Each well takes 100 µl and gives 0.34 cm² of growth area, on a #1.5 ibidi Polymer Coverslip bottom 180 µm thick. Eighteen conditions, or six conditions in triplicate, on one slide that goes straight onto the stage.

The reason to use it is cost per data point. An antibody titration across eighteen wells at 100 µl each consumes very little reagent and very few cells, and the whole thing is imaged in one pass without moving anything.

Immunofluorescence without the coverslipping

Fix, permeabilise, block and stain in the wells. The bottom is already coverslip grade, so there is no mounting a coverslip and no cells lost in the transfer. The walls do not leak between wells during the incubations, which is the part that actually decides whether an 18 well format is usable.

Where I would not spend the money

If the method is TIRF, single molecule detection or super-resolution, buy the Glass Bottom version, 81817, and pay the difference. For widefield and confocal immunofluorescence the polymer bottom here is the better value and I would not push you to the glass. If eighteen wells is more than you will realistically fill, the µ-Slide 8 Well gives more area and volume per well on the same footprint and is easier to handle.

Key Features

  • 18 wells on a standard 25.5 x 75.5 mm slide footprint
  • 0.34 cm² growth area and 100 µl per well
  • #1.5 ibidi Polymer Coverslip bottom, 180 µm
  • No leakage between wells during staining steps
  • ibiTreat (81816) or uncoated (81811), 15, 90 or 120 per box

NEED MORE INFORMATION ABOUT THIS PRODUCT?

Send us your emailSend us your email
Catalog number81816 ibiTreat, 81811 uncoated
Number of wells18
Growth area per well0.34 cm²
Coating area per well1.15 cm²
Volume per well100 µl
Well dimensions5.7 x 6.1 x 6.8 mm
Outer dimensions25.5 x 75.5 mm
Height with lid8.2 mm
Height without lid6.8 mm
Coverslip#1.5 ibidi Polymer, 180 µm (+10/-5 µm)
SurfaceibiTreat tissue culture treated, or uncoated hydrophobic
SterilizationSterilized, sealed in gas permeable packaging
StorageRT (15 to 25 °C)
Shelf life36 months
Pieces per box15 or 90 individually packed, or 120 at 8 per tray

Applications

  • Immunofluorescence staining
  • Multi-condition screening with small cell numbers
  • Antibody and compound titrations
  • Live cell imaging
  • Fluorescence and confocal microscopy

ibidi u-Slide 18 Well seen from above showing the well array
ibidi u-Slide 18 Well with lid

Cell Cultivation and Imaging

Explore All Products

Fluorescence Imaging

Explore All Products
Research publications using ibidi microfluidic devices and culture formats

Comprehensive collection of peer-reviewed research publications demonstrating the use of ibidi labware including µ-Slides, µ-Dishes, µ-Plates, and specialized microfluidic devices for cell biology, neurobiology, vascular biology, and cancer research.

Why eighteen wells rather than eight?

Cost per data point. At 100 µl and 0.34 cm² per well, a titration across eighteen wells uses very little antibody and very few cells, and it is imaged in one pass. If you will not realistically fill eighteen wells, the µ-Slide 8 Well gives more area and volume per well on the same footprint and is easier to handle.

Do the wells leak into each other during staining?

No. That is the thing that decides whether an 18 well format is usable at all, and it is why the walls are moulded the way they are. Fix, permeabilise, block and stain in the wells.

Do I need to mount a coverslip afterwards?

No. The bottom is already coverslip grade at 180 µm, so the slide goes straight onto an inverted microscope. Nothing is transferred and nothing is lost.

81816, 81811 or 81817?

81816 is ibiTreat on a polymer bottom, which is what most immunofluorescence needs. 81811 is the uncoated version, for your own coating. 81817 is the Glass Bottom version, and it is the one to buy for TIRF, single molecule detection and super-resolution. For widefield and confocal I would stay with 81816 and keep the difference.

Is it available in Israel with local support?

Yes. NBT is the ibidi distributor in Israel. We hold labware locally, and we will tell you when a cheaper item in the range does the same job.

Still have questions?

Can’t find the answer you’re looking for? Please chat to our friendly team.

Request for Quote

Please fill in as much details as possible and we will take care of your request as soon as possible

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Request for Quote

Please fill in as much details as possible and we will take care of your request as soon as possible

Request Quote
X
Let's discuss your specific needs