Axon™ Digidata® 1550B plus HumSilencer®

The Axon™ Digidata® 1550B plus HumSilencer® is the premier patch-clamp digitizer for electrophysiology — delivering simultaneous 500 kHz sampling on 8 channels with 16-bit resolution, and the industry-first HumSilencer® technology that intelligently eliminates 50/60 Hz line-frequency noise without any signal distortion.

Axon™ Digidata® 1550B plus HumSilencer®

The Digitizer That Enables World-Class Patch-Clamp Data Acquisition

The Axon™ Digidata® 1550B plus HumSilencer® is one of the most advanced analog-to-digital signal converters available for electrophysiology research. Designed for patch-clamp, voltage-clamp, and current-clamp experiments, it combines 16-bit resolution at up to 500 kHz sampling with the revolutionary HumSilencer® technology — a first-of-its-kind, intelligent noise-cancellation system built directly into the digitizer hardware.

The Digidata 1550B pairs seamlessly with pCLAMP™ 11 Software and is compatible with the full range of Axon Instruments amplifiers including the MultiClamp 700B and Axoclamp 900A. Its USB 2.0 connection requires no separate power supply, making it straightforward to integrate into any patch-clamp rig.

Key Features

  • HumSilencer® Noise Cancellation: Learns, adapts, and eliminates local 50/60 Hz line-frequency electrical hum and high-frequency harmonics from up to four input channels simultaneously — in less than one second. Unlike notch filters, HumSilencer causes no signal distortion, no phase shift, no amplitude attenuation, and no DC offset.
  • 500 kHz Simultaneous Sampling: All eight analog input channels can be digitized simultaneously at up to 500 kHz per channel, enabling the acquisition of fast, high-resolution ionic currents with exceptional temporal detail.
  • 16-Bit Resolution: With 16-bit ADC resolution across an input range of ±10 V, the Digidata 1550B resolves small, physiologically relevant signals with minimal quantization error.
  • 8 Analog Input + 8 Analog Output Channels: Supports complex multi-channel recording configurations — essential for multi-electrode setups, voltage-clamp ramps, and pharmacology protocols requiring simultaneous analog output commands.
  • Three HumSilencer Configurations: Choose the model that matches your setup: 1550B4 (4-channel HumSilencer), 1550B1 (1-channel), or 1550B0 (no HumSilencer), all sharing the same core digitizer platform.
  • USB 2.0 Connectivity: Plug-and-play USB connection with a 3-meter braided cable — no PCIe card, no separate power brick. Clean, minimal bench footprint.
  • TTL I/O and TAG Input: Dedicated digital I/O lines for synchronizing external devices such as shutters, perfusion systems, and stimulators. Rising-edge sensitive TAG input for event timestamping.

NEED MORE INFORMATION ABOUT THIS PRODUCT?

Send us your emailSend us your email

Technical Specifications

Catalog NumberDD-1550B4 (4-ch HumSilencer), DD-1550B1 (1-ch HumSilencer), DD-1550B0 (no HumSilencer)
Resolution16-bit
Analog Input Channels8 single-ended
Number of ADCs8
Sampling Rate1 Hz – 500 kHz per channel (simultaneous)
Input Range−10.000 V to +10.000 V
Maximum Input Signal±10 V (signal + noise combined)
Maximum Noise Amplitude20 V peak-to-peak (on a 0 V signal)
Input Resistance>1 MΩ
Gain1 (fixed)
Analog Output Channels8
Number of DACs8
Output Range−10.000 V to +10.000 V
Output Impedance<0.5 Ω
Output Short Circuit Current±25 mA to signal ground
HumSilencer Noise CancellationLine-frequency (50/60 Hz) and harmonics up to 10 kHz
Cancellation Response Time<1 second
HumSilencer ChannelsUp to 4 (model 1550B4)
Digital I/O8-bit (of 16) supported in software
Scope Trigger OutputDedicated; Advanced CMOS (AC) compatible; ±4 mA source
TAG InputTTL compatible, rising-edge sensitive
PC InterfaceUSB 2.0, braided cable, 3 meters
Compatible SoftwarepCLAMP™ 11
Compatible AmplifiersMultiClamp 700B, Axoclamp 900A, Axopatch 200B

Applications

  • Patch-clamp electrophysiology (whole-cell, cell-attached, inside-out, outside-out)
  • Voltage-clamp and current-clamp recordings in neurons, cardiac myocytes, and oocytes
  • Ion channel pharmacology and drug discovery
  • Cellular network electrophysiology with HumSilencer noise elimination
  • Multi-electrode recording configurations

Axon Digidata 1550B plus HumSilencer product view
Axon Digidata 1550B - patch clamp system setup
Axon Digidata 1550B - diagram and specifications
Peer-reviewed research using the Axon Digidata 1550B

The Axon Digidata 1550B is widely cited in patch-clamp electrophysiology studies across neuroscience, cardiology, and pharmacology. Researchers rely on it to acquire high-fidelity ionic current recordings in neurons, cardiomyocytes, and Xenopus oocytes, often in combination with MultiClamp 700B amplifiers and pCLAMP software.

Request for Quote

Please fill in as much details as possible and we will take care of your request as soon as possible

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Request for Quote

Please fill in as much details as possible and we will take care of your request as soon as possible

Request Quote
X
Let's discuss your specific needs