ONE AMPLIFIER. MULTIPLE CONNECTORS

g.Nautilus PRO FLEXIBLE is a CE-certified and FDA cleared wearable EEG headset to record brain activity in medical and clinical environments. It’s available with 8/16/19/32 dry or wet EEG electrodes that can be plugged into the headset.

This makes the device especially suited for medical applications because multiple caps can be used with one headset and the cleaning is easier.

g.Nautilus PRO FLEXIBLE allows to plug-in electrode strands with g.SAHARA hybrid EEG electrodes or g.SCARABEO wet EEG electrodes. Simply pick an electrode strand best suited for your appliation. The different electrode strands hold 8/16/19/32 EEG electrodes. Additional Safety Connectors allow you to plug in different types of body sensors.

  • Strand g.SCARABEO
  • Strand g.SAHARA Hybrid
  • Strand g.SCARABEO + 4  Safety Connectors
  • Strand g.SAHARA Hybrid + 4  Safety Connectors
  • Strand Safety Connectors Only

PRODUCT HIGHLIGHTS

Electrode strands can be plugged into the headset
Strand with g.SAHARA hybrid EEG electrodes for dry and gel recordings
Strand with g.SCARABEO EEG electrodes for wet recordings
Strand with safety sockets to connect g.SCARABEO, g.SAHARA hybrid or g.Sensors
Easy cleaning of the electrode strands; fits ideally for medical applications
8/16/19/32 channels wearable EEG with 3-axis accelerometer
24-bit accuracy at 500 Hz sampling rate
2.4 GHz digital transmission, range: 10 meters indoor
10 hours continuous recording and 2-3 hours charging
Internal impedance check with for g.SCARABEO electrodes
A new benchmark in usability
Full software environment
CE certified and FDA cleared medical EEG headset

TECHNICAL SPECIFICATIONS

Weight < 110 g without electrode grid
Size 78 (L) x 94 (W) x 26 (H) mm
Color BLACK
Sensitivity ±2.25 V, ±1.125 V, ±750 mV, ±562,5 mV, ±375 mV, ±187.5 mV (software selectable)
Interface Wireless 2.4 GHz ISM band
Digital inputs 8 digital trigger inputs at Base Station
Supply Built-in lithium ion battery, runtime > 10 h with 32 channels, inductive charging according to the QI standard of the Wireless Power Consortium
Amplifier type Real DC coupled
32 × ADC 24 Bit (1.024 MHz internal sampling per channel)
Noise level < 0.6 µV RMS between 1 and 30 Hz (at highest input sensitivity)
Input channels 32 mono-polar / 16 bi-polar channels with GND and REF (software selectable)
Input impedance DC > 100 MOhm
Applied part BF
Safety class II
Certification and Standards CE certified and FDA cleared medical device IEC60601-1 3rd, IEC60601-1-2, IEC62304, IEC60601-2-26, ISO 14971 10993-1, 62366, 2010-2012 IEEE Recommended Practice for Neurofeedback Systems