OPAL Optical O2 Measurement System

Versatile system for measuring the oxygen concentration in cell cultures or tissues.

Product Image

OpalController RGB Opal RGB 

More Information

  • Fast measurement within seconds
  • High spatial resolution
  • Non-invasive and real-time measurements
  • Ideal for in vitro hypoxia conditions, like 3D cultures, spheroid models, and tissue

Applications

  • Exact oxygen measurement in cell cultures or tissue
  • Ideal for in vitro hypoxia conditions, like 3D cultures, spheroid models, and tissue

In addition to controlling the oxygen concentration in the stage top incubator, it is indispensable to know the real oxygen concentration near the cells (monitoring extracellular O2), or even inside the cells (intracellular O2). Because cells consume oxygen, the concentrations are typically much lower in cell clusters, such as tissue or spheroids.

With the ibidi OPAL Optical O2 Measurement Sytem, the oxygen concentration can be measured optically and directly in a 2D cell culture dish, a compact 3D cell spheroid, or even in a piece of tissue. Oxygen-sensitive beads or cell-permeable fluorophores are utilized to measure the fluorescence lifetime.

Note: The OPAL System measures lifetimes in the range of 1-1,000 µsec (i.e., phosphorescence). To keep things simple, ibidi uses the more common term fluorescence, instead of phosphorescence.

Compatibility to Microscopes
The ibidi OPAL System can be connected to all modern inverted microscopes from Nikon, Olympus, Leica, and Zeiss. Small adaptations need to be made, and during this process, ibidi will comprehensively support you. These adaptations include a specialized OPAL Filter Set and an LED Light Source Coupler for the microscope (included in the ibidi OPAL System). The OPAL Detector Unit fits the standard C-Mount camera port, or can also be mounted on an ocular.

Extracellular O2 Monitoring
Oxygen monitoring is defined as the measurements of O2 in the direct neighborhood of cultured cells. Oxygen sensitive beads, with a diameter of 50 µm (CPOx), are used in combination with the ibidi OPAL system or a FLIM microscope to measure the oxygen concentration.

Intracellular O2 Measurement
For intracellular oxygen measurements, an oxygen-sensitive nanoparticle reagent is brought into the cells. The ibidi OPAL System or FLIM microscopes reveal quantitative O2concentrations by identifying a change in the lifetime of the fluorophore NanO2.